The Radial Neutron Camera is an ITER diagnostic designed to measure the un-collided 14 MeV and 2.5 MeV neutrons from deuterium-tritium (DT) and deuterium-deuterium (DD) fusion reactions, through an array of detectors covering a poloidal plasma section along collimated Lines Of Sight (LOS). It is composed by two fanshaped collimating structures viewing the plasma radially through vertical slots in the diagnostic shielding module of ITER Equatorial Port 1: the In-Port RNC, devoted to plasma edge coverage, and the Ex-Port RNC, devoted to the plasma core coverage. This paper presents an overview of the mechanical design of the Ex-Port RNC at the Preliminary Design Review (PDR) stage. The Ex-Port RNC is located in the Port Interspace and consists of a massive shielding structure hosting the detector units and two sets of collimators lying on different toroidal planes. The Ex-Port RNC design is presented both from the point of view of functional requirements (e.g. LOS positions and angles, radiation shielding, weight limitations) and of manufacturability. Finally, the Ex-port RNC structural integrity is assessed, and its design validated against the main loads and load combinations.
Mechanical design of ITER radial neutron camera Ex-Port system
Marzullo, Domenico;Occhiuto, Enrico
;
2024-01-01
Abstract
The Radial Neutron Camera is an ITER diagnostic designed to measure the un-collided 14 MeV and 2.5 MeV neutrons from deuterium-tritium (DT) and deuterium-deuterium (DD) fusion reactions, through an array of detectors covering a poloidal plasma section along collimated Lines Of Sight (LOS). It is composed by two fanshaped collimating structures viewing the plasma radially through vertical slots in the diagnostic shielding module of ITER Equatorial Port 1: the In-Port RNC, devoted to plasma edge coverage, and the Ex-Port RNC, devoted to the plasma core coverage. This paper presents an overview of the mechanical design of the Ex-Port RNC at the Preliminary Design Review (PDR) stage. The Ex-Port RNC is located in the Port Interspace and consists of a massive shielding structure hosting the detector units and two sets of collimators lying on different toroidal planes. The Ex-Port RNC design is presented both from the point of view of functional requirements (e.g. LOS positions and angles, radiation shielding, weight limitations) and of manufacturability. Finally, the Ex-port RNC structural integrity is assessed, and its design validated against the main loads and load combinations.File | Dimensione | Formato | |
---|---|---|---|
1-s2.0-S0920379624003302-main.pdf
accesso aperto
Tipologia:
Documento in Versione Editoriale
Licenza:
Creative commons
Dimensione
8.68 MB
Formato
Adobe PDF
|
8.68 MB | Adobe PDF | Visualizza/Apri |
Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.