Large Area Picosecond PhotoDetectors (LAPPDs) are photosensors based on microchannel plate technology with about 400 cm2 sensitive area. The external readout plane of a capacitively coupled LAPPD can be segmented into pads providing a spatial resolution down to 1 mm scale. The LAPPD signals have about 0.5 ns rise time followed by a slightly longer fall time and their amplitude reaches a few dozens of mV per single photoelectron. In this article, we report on the measurement of the time resolution of an LAPPD prototype in a test beam exercise at CERN PS. Most of the previous measurements of LAPPD time resolution had been performed with laser sources. In this article we report time resolution measurements obtained through the detection of Cherenkov radiation emitted by high energy hadrons. Our approach has been demonstrated capable of measuring time resolutions as fine as 25-30 ps. The available prototype had performance limitations, which prevented us from applying the optimal high voltage setting. The measured time resolution for single photoelectrons is about 80 ps r.m.s.
Characterization of LAPPD timing at CERN PS testbeam
Bressan, Andrea;Chatterjee, Chandradoy;Torre, Silvia Dalla;Levorato, Stefano;Martin, Anna;
2024-01-01
Abstract
Large Area Picosecond PhotoDetectors (LAPPDs) are photosensors based on microchannel plate technology with about 400 cm2 sensitive area. The external readout plane of a capacitively coupled LAPPD can be segmented into pads providing a spatial resolution down to 1 mm scale. The LAPPD signals have about 0.5 ns rise time followed by a slightly longer fall time and their amplitude reaches a few dozens of mV per single photoelectron. In this article, we report on the measurement of the time resolution of an LAPPD prototype in a test beam exercise at CERN PS. Most of the previous measurements of LAPPD time resolution had been performed with laser sources. In this article we report time resolution measurements obtained through the detection of Cherenkov radiation emitted by high energy hadrons. Our approach has been demonstrated capable of measuring time resolutions as fine as 25-30 ps. The available prototype had performance limitations, which prevented us from applying the optimal high voltage setting. The measured time resolution for single photoelectrons is about 80 ps r.m.s.File | Dimensione | Formato | |
---|---|---|---|
2024_NIMA1058_168937.pdf
Accesso chiuso
Descrizione: Articolo
Tipologia:
Documento in Versione Editoriale
Licenza:
Copyright Editore
Dimensione
2.04 MB
Formato
Adobe PDF
|
2.04 MB | Adobe PDF | Visualizza/Apri Richiedi una copia |
Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.