The mass of the Higgs boson is measured in the Hāγγ decay channel, exploiting the high resolution of the invariant mass of photon pairs reconstructed from the decays of Higgs bosons produced in protonāproton collisions at a centre-of-mass energy s=13 TeV. The dataset was collected between 2015 and 2018 by the ATLAS detector at the Large Hadron Collider, and corresponds to an integrated luminosity of 140 fbā1. The measured value of the Higgs boson mass is 125.17±0.11(stat.)±0.09(syst.) GeV and is based on an improved energy scale calibration for photons, whose impact on the measurement is about four times smaller than in the previous publication. A combination with the corresponding measurement using 7 and 8 TeV pp collision ATLAS data results in a Higgs boson mass measurement of 125.22±0.11(stat.)±0.09(syst.) GeV. With an uncertainty of 1.1 per mille, this is currently the most precise measurement of the mass of the Higgs boson from a single decay channel. Ā© 2023 The Author(s)
Measurement of the Higgs boson mass with š» ā š¾š¾ decays in 140 fbā1 of āš = 13 TeV šš collisions with the ATLAS detector / Atlas, C., Gonella, L.. - In: PHYSICS LETTERS. SECTION B. - ISSN 0370-2693. - 847/2023:(2023), pp. 138315.1-138315.23. [10.1016/j.physletb.2023.138315]
Measurement of the Higgs boson mass with š» ā š¾š¾ decays in 140 fbā1 of āš = 13 TeV šš collisions with the ATLAS detector
GONELLA, Laura
2023-01-01
Abstract
The mass of the Higgs boson is measured in the Hāγγ decay channel, exploiting the high resolution of the invariant mass of photon pairs reconstructed from the decays of Higgs bosons produced in protonāproton collisions at a centre-of-mass energy s=13 TeV. The dataset was collected between 2015 and 2018 by the ATLAS detector at the Large Hadron Collider, and corresponds to an integrated luminosity of 140 fbā1. The measured value of the Higgs boson mass is 125.17±0.11(stat.)±0.09(syst.) GeV and is based on an improved energy scale calibration for photons, whose impact on the measurement is about four times smaller than in the previous publication. A combination with the corresponding measurement using 7 and 8 TeV pp collision ATLAS data results in a Higgs boson mass measurement of 125.22±0.11(stat.)±0.09(syst.) GeV. With an uncertainty of 1.1 per mille, this is currently the most precise measurement of the mass of the Higgs boson from a single decay channel. Ā© 2023 The Author(s)| File | Dimensione | Formato | |
|---|---|---|---|
|
1-s2.0-S0370269323006494-main.pdf
accesso aperto
Tipologia:
Documento in Versione Editoriale
Licenza:
Creative commons
Dimensione
2.66 MB
Formato
Adobe PDF
|
2.66 MB | Adobe PDF | Visualizza/Apri |
Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.


