This paper describes the performance of the LABDOS01, a silicon diode-based spectrometer suitable for dose measurements in mixed radiation fields. The instrument is currently being used in two high-altitude environmental dose monitoring projects: SAMADHA (South Atlantic Magnetic Anomaly Dosimetry at High Altitude) at Chacaltaya (Bolivia, 5240 m a.s.l.) and CORDIAL (COsmic Rays Dosimetry In Antarctic Latitudes) at the Concordia station (Antarctica, 3233 m a.s.l.). Before installing two of these devices at the measurement sites, the detectors were tested on flight routes covering a wide range of geomagnetic latitudes. The collected dosimetric data were compared with the expectations derived by the CARI-7A software, which provides the absorbed dose rate in silicon due to cosmic ray secondaries at a given position on the Earth. The measured dose rates along the flights at variable altitude and rigidity cutoff agree well with the simulated ones. By analyzing the spectrum of the energy deposited in the silicon layer, we derive an empirical method to approximately evaluate the ambient dose equivalent 𝐻∗ (10), a quantity directly related to the biological damage caused by environmental radiation.

Performance of the LABDOS01 spectrometer in dosimetric measurements

Cirilli, Stefano;Romanelli, Fabio;
2025-01-01

Abstract

This paper describes the performance of the LABDOS01, a silicon diode-based spectrometer suitable for dose measurements in mixed radiation fields. The instrument is currently being used in two high-altitude environmental dose monitoring projects: SAMADHA (South Atlantic Magnetic Anomaly Dosimetry at High Altitude) at Chacaltaya (Bolivia, 5240 m a.s.l.) and CORDIAL (COsmic Rays Dosimetry In Antarctic Latitudes) at the Concordia station (Antarctica, 3233 m a.s.l.). Before installing two of these devices at the measurement sites, the detectors were tested on flight routes covering a wide range of geomagnetic latitudes. The collected dosimetric data were compared with the expectations derived by the CARI-7A software, which provides the absorbed dose rate in silicon due to cosmic ray secondaries at a given position on the Earth. The measured dose rates along the flights at variable altitude and rigidity cutoff agree well with the simulated ones. By analyzing the spectrum of the energy deposited in the silicon layer, we derive an empirical method to approximately evaluate the ambient dose equivalent 𝐻∗ (10), a quantity directly related to the biological damage caused by environmental radiation.
File in questo prodotto:
File Dimensione Formato  
1-s2.0-S0969806X25005237-main.pdf

Accesso chiuso

Tipologia: Documento in Versione Editoriale
Licenza: Copyright Editore
Dimensione 2.6 MB
Formato Adobe PDF
2.6 MB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11368/3112024
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? 0
social impact