X-ray phase contrast imaging (XPCI) records phase shifts in X-rays as they pass through matter, enabling the distinction of features, such as soft tissues, that have low contrast in conventional absorption-based methods. Phase contrast beam tracking technique uses an absorbing mask to shape the X-ray beam into an array of beamlets before they reach the detector. Analyzing these beamlets provides information on X-ray absorption, refraction (differential phase), and ultra-small-angle scattering. In XPCI, mask visibility is typically defined as the ratio between the standard deviation and the mean value measured from a chosen region in the mask image. The primary focus of this study is to investigate the influence of detector spatial resolution on mask visibility. Three different scintillator-coupled scientific CMOS detectors, with varying pixel sizes and scintillator thicknesses, were tested to highlight the difference in response in terms of visibility from a given mask. Additionally, the impact of visibility on the image quality in refraction images was investigated through a wave optics simulation. The results showcase the trends of contrast and signal-to-noise ratio values as a function of mask visibility. This work is part of the development of a novel setup for combined X-ray Spectral Imaging (XSI) and XPCI undertaken by INFN's Sphere-X project implemented at the Elettra Sincrotrone Trieste.

Spectral phase-contrast X-ray imaging with high-resolution detectors

Perion, P.
Primo
;
Brombal, L.
Secondo
;
Brun, F.;Sbuelz, L.;Arfelli, F.
Ultimo
2025-01-01

Abstract

X-ray phase contrast imaging (XPCI) records phase shifts in X-rays as they pass through matter, enabling the distinction of features, such as soft tissues, that have low contrast in conventional absorption-based methods. Phase contrast beam tracking technique uses an absorbing mask to shape the X-ray beam into an array of beamlets before they reach the detector. Analyzing these beamlets provides information on X-ray absorption, refraction (differential phase), and ultra-small-angle scattering. In XPCI, mask visibility is typically defined as the ratio between the standard deviation and the mean value measured from a chosen region in the mask image. The primary focus of this study is to investigate the influence of detector spatial resolution on mask visibility. Three different scintillator-coupled scientific CMOS detectors, with varying pixel sizes and scintillator thicknesses, were tested to highlight the difference in response in terms of visibility from a given mask. Additionally, the impact of visibility on the image quality in refraction images was investigated through a wave optics simulation. The results showcase the trends of contrast and signal-to-noise ratio values as a function of mask visibility. This work is part of the development of a novel setup for combined X-ray Spectral Imaging (XSI) and XPCI undertaken by INFN's Sphere-X project implemented at the Elettra Sincrotrone Trieste.
2025
Pubblicato
File in questo prodotto:
File Dimensione Formato  
Perion_2025_J._Inst._20_C06056.pdf

accesso aperto

Tipologia: Documento in Versione Editoriale
Licenza: Creative commons
Dimensione 7.39 MB
Formato Adobe PDF
7.39 MB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11368/3116921
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 1
social impact