Background: Transcatheter aortic valve implantation (TAVI) is increasingly performed in younger and lower-risk patients. Since many of these patients will outlive their transcatheter heart valve (THV), redo-TAVI procedures are expected to rise in number. Yet, real-world evidence on the procedural safety and efficacy of redo-TAVI remains limited. Aims: We aimed to evaluate the 30-day procedural and clinical outcomes of redo-TAVI using the balloon-expandable SAPIEN 3 platform. Methods: The ReTAVI registry is a prospective, international study enrolling consecutive patients with a failed aortic THV undergoing redo-TAVI with a balloon-expandable SAPIEN 3 THV. Data were collected across 59 international centres. All imaging was centrally analysed, and major clinical events were adjudicated by an independent committee. Results: â¨A total of 143 patients (median age 84 years; 40.6% female; median Society of Thoracic Surgeons risk score 7.0%) were enrolled. The predominant failing THVs were balloon-expandable SAPIEN 3 (30.1%), self-expanding CoreValve/Evolut (53.1%), and ACURATE (14.0%) platforms. The most common failure mode was isolated regurgitation (48.6%), followed by stenosis (35.2%) and a mixed pathology (16.2%). The replacement valve was successfully implanted in 95.1% of patients, with a 30-day mortality rate of 3.5%. The 30-day stroke and pacemaker implantation rates were 0.7% and 6.3%, respectively. Redo-TAVI significantly improved valve haemodynamics, with mean gradients decreasing overall (Δ=-12.0 mmHg), and a more pronounced reduction in stenotic failures (Δ=-29.0 mmHg). Coronary obstruction was observed in 1.4% of cases. Conclusions: Redo-TAVI with a balloon-expandable SAPIEN 3 THV platform is a safe and effective reintervention strategy across diverse failed THV types, when guided by the Heart Team, standardised procedural planning, and comprehensive imaging. Clinicaltrials: gov: NCT05601453.
Early outcomes of redo-TAVI with the SAPIEN 3 platform: the prospective, multicentre ReTAVI registry / Tarantini, G., Fovino, L.N., Alvarez Covarrubias, H.A., Wolny, R., Fabris, T., Skipirzepa, J.N., Eden, M., Zamorano, J.L., Joner, M., Cuisset, T., Delgado, V., Rodés-Cabau, J., Saia, F., Bieliauskas, G., Van Belle, E., Modine, T., Rheude, T., Garot, P., Jung, C., Rudolph, T.K., et al.. - In: EUROINTERVENTION. - ISSN 1969-6213. - 22:11(2026), pp. e629-e641. [10.4244/EIJ-D-25-01268]
Early outcomes of redo-TAVI with the SAPIEN 3 platform: the prospective, multicentre ReTAVI registry
Fabris, Enrico;
2026-01-01
Abstract
Background: Transcatheter aortic valve implantation (TAVI) is increasingly performed in younger and lower-risk patients. Since many of these patients will outlive their transcatheter heart valve (THV), redo-TAVI procedures are expected to rise in number. Yet, real-world evidence on the procedural safety and efficacy of redo-TAVI remains limited. Aims: We aimed to evaluate the 30-day procedural and clinical outcomes of redo-TAVI using the balloon-expandable SAPIEN 3 platform. Methods: The ReTAVI registry is a prospective, international study enrolling consecutive patients with a failed aortic THV undergoing redo-TAVI with a balloon-expandable SAPIEN 3 THV. Data were collected across 59 international centres. All imaging was centrally analysed, and major clinical events were adjudicated by an independent committee. Results: â¨A total of 143 patients (median age 84 years; 40.6% female; median Society of Thoracic Surgeons risk score 7.0%) were enrolled. The predominant failing THVs were balloon-expandable SAPIEN 3 (30.1%), self-expanding CoreValve/Evolut (53.1%), and ACURATE (14.0%) platforms. The most common failure mode was isolated regurgitation (48.6%), followed by stenosis (35.2%) and a mixed pathology (16.2%). The replacement valve was successfully implanted in 95.1% of patients, with a 30-day mortality rate of 3.5%. The 30-day stroke and pacemaker implantation rates were 0.7% and 6.3%, respectively. Redo-TAVI significantly improved valve haemodynamics, with mean gradients decreasing overall (Δ=-12.0 mmHg), and a more pronounced reduction in stenotic failures (Δ=-29.0 mmHg). Coronary obstruction was observed in 1.4% of cases. Conclusions: Redo-TAVI with a balloon-expandable SAPIEN 3 THV platform is a safe and effective reintervention strategy across diverse failed THV types, when guided by the Heart Team, standardised procedural planning, and comprehensive imaging. Clinicaltrials: gov: NCT05601453.| File | Dimensione | Formato | |
|---|---|---|---|
|
Tarantini et al. 2026, Early outcomes of ReTAVI with S3.pdf
Accesso chiuso
Tipologia:
Documento in Versione Editoriale
Licenza:
Copyright Editore
Dimensione
2.03 MB
Formato
Adobe PDF
|
2.03 MB | Adobe PDF | Visualizza/Apri Richiedi una copia |
Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.