Objectives To investigate prospectively the relation between vibration-induced white finger (VWF), exposure to hand-trasmitted vibration (HTV) and the cold response of digital arteries in users of vibrating tools. Methods Two-hundred and sixteen HTV workers and 133 control men of the same companies underwent initially a medical examination and a standardised cold test with measurement of the change in finger systolic blood pressure (FSBP) after finger cooling from 30 to 10C. They were re-examined 1 year later. Tool vibration magnitudes were expressed as frequency-weighted and unweighted r.m.s. accelerations. From the vibration magnitudes and exposure durations, alternative measures of cumulative vibration dose were calculated for each HTV worker, according to the expression: dose ¼ Pami ti, where ai is the acceleration magnitude on tool i, ti is the lifetime exposure duration for tool i, and m = 0, 1, 2 or 4. Results Among the HTV workers, the initial prevalence and the 1-year incidence of VWF were 18.1 and 1.7%, respectively. At the first examination, the HTV workers with moderate or severe score for VWF showed a significantly increased cold reaction in the fingers when compared with the controls and the HTV workers with no vascular symptoms. At the follow-up, the controls, the asymptomatic HTV workers, and the prevalent cases of VWF did not show significant changes in the cold response of digital arteries. A deterioration of cold-induced digital vasoconstriction was found in the incident cases of VWF. In the HTV workers, vibration doses with high powers of acceleration (i.e., dose ¼ Pami ti with m[1) were major predictors of the vasoconstrictor response to cold at the follow-up examination. Conclusions The measurement of FSBP after local cooling may be a helpful objective test to monitor prospectively the change in vibration-induced vascular symptoms. The findings of this longitudinal study suggest a dose–effect relationship between cold-induced digital arterial hyperresponsiveness over time and measures of cumulative vibration exposure. In the controls, the cold response of the digital arteries was stable over 1-year follow- up period.

A longitudinal study of finger systolic blood pressure and exposure to hand-transmitted vibration

BOVENZI, MASSIMO;NEGRO, CORRADO
2007-01-01

Abstract

Objectives To investigate prospectively the relation between vibration-induced white finger (VWF), exposure to hand-trasmitted vibration (HTV) and the cold response of digital arteries in users of vibrating tools. Methods Two-hundred and sixteen HTV workers and 133 control men of the same companies underwent initially a medical examination and a standardised cold test with measurement of the change in finger systolic blood pressure (FSBP) after finger cooling from 30 to 10C. They were re-examined 1 year later. Tool vibration magnitudes were expressed as frequency-weighted and unweighted r.m.s. accelerations. From the vibration magnitudes and exposure durations, alternative measures of cumulative vibration dose were calculated for each HTV worker, according to the expression: dose ¼ Pami ti, where ai is the acceleration magnitude on tool i, ti is the lifetime exposure duration for tool i, and m = 0, 1, 2 or 4. Results Among the HTV workers, the initial prevalence and the 1-year incidence of VWF were 18.1 and 1.7%, respectively. At the first examination, the HTV workers with moderate or severe score for VWF showed a significantly increased cold reaction in the fingers when compared with the controls and the HTV workers with no vascular symptoms. At the follow-up, the controls, the asymptomatic HTV workers, and the prevalent cases of VWF did not show significant changes in the cold response of digital arteries. A deterioration of cold-induced digital vasoconstriction was found in the incident cases of VWF. In the HTV workers, vibration doses with high powers of acceleration (i.e., dose ¼ Pami ti with m[1) were major predictors of the vasoconstrictor response to cold at the follow-up examination. Conclusions The measurement of FSBP after local cooling may be a helpful objective test to monitor prospectively the change in vibration-induced vascular symptoms. The findings of this longitudinal study suggest a dose–effect relationship between cold-induced digital arterial hyperresponsiveness over time and measures of cumulative vibration exposure. In the controls, the cold response of the digital arteries was stable over 1-year follow- up period.
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11368/1717909
 Avviso

Registrazione in corso di verifica.
La registrazione di questo prodotto non è ancora stata validata in ArTS.

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 15
  • ???jsp.display-item.citation.isi??? 14
social impact