Heparin is still widely used for treatment and prevention of thromboembolic diseases. Due to specific physicochemical properties, it requires frequent parenteral injections. In this study we present the development and in vitro evaluation of an advanced delivery system for prolonged subcutaneous release of heparin. The delivery system consisted of an in situ forming thermoresponsive poloxamer-based platform combined with pH-responsive polyelectrolyte heparin/chitosan nanocomplexes. Thermoresponsive hydrogels were tested for gelation temperature, gel dissolution and in vitro heparin release, whereas polyelectrolyte nanocomplexes were physico-chemically characterized, as well as tested for in vitro cytotoxicity and in vitro heparin release. Hydrogel combined of two poloxamers demonstrated the highest gelation temperature (28.6 C), while the addition of hydroxypropyl methylcellulose prolonged gel dissolution. On the other hand, nanocomplexes’ dispersions, prepared at 1:1 heparin/chitosan mass ratio and in the concentration range 0.375–1.875 mg/mL, demonstrated mean diameter <400 nm and zeta potential >34 mV. Pharmacokinetics of selected formulations (thermoresponsive hydrogel, nanocomplexes and a dual system consisting of nanocomplexes incorporated into thermoresponsive hydrogel) were studied in rats. Heparin plasma concentration-time profiles revealed a double-peak phenomenon, probably due to heparin diffusion inside the polymer matrix and gel dissolution. Pharmacokinetic parameters were determined by a non-linear mixed effects modeling approach. It was demonstrated that thermoresponsive hydrogel with heparin/chitosan nanocomplexes enabled the lowest absorption rate of heparin into systemic circulation and provided heparin concentration above the prophylaxis threshold for 5 days. In situ gelling thermoresponsive matrix combined with chitosan nanocomplexes present a promising delivery system for heparin, requiring less frequent administration during long-term treatment.

Development and preclinical pharmacokinetics of a novel subcutaneous thermoresponsive system for prolonged delivery of heparin

VOINOVICH, DARIO;GOLOB, SAMUEL;
2015-01-01

Abstract

Heparin is still widely used for treatment and prevention of thromboembolic diseases. Due to specific physicochemical properties, it requires frequent parenteral injections. In this study we present the development and in vitro evaluation of an advanced delivery system for prolonged subcutaneous release of heparin. The delivery system consisted of an in situ forming thermoresponsive poloxamer-based platform combined with pH-responsive polyelectrolyte heparin/chitosan nanocomplexes. Thermoresponsive hydrogels were tested for gelation temperature, gel dissolution and in vitro heparin release, whereas polyelectrolyte nanocomplexes were physico-chemically characterized, as well as tested for in vitro cytotoxicity and in vitro heparin release. Hydrogel combined of two poloxamers demonstrated the highest gelation temperature (28.6 C), while the addition of hydroxypropyl methylcellulose prolonged gel dissolution. On the other hand, nanocomplexes’ dispersions, prepared at 1:1 heparin/chitosan mass ratio and in the concentration range 0.375–1.875 mg/mL, demonstrated mean diameter <400 nm and zeta potential >34 mV. Pharmacokinetics of selected formulations (thermoresponsive hydrogel, nanocomplexes and a dual system consisting of nanocomplexes incorporated into thermoresponsive hydrogel) were studied in rats. Heparin plasma concentration-time profiles revealed a double-peak phenomenon, probably due to heparin diffusion inside the polymer matrix and gel dissolution. Pharmacokinetic parameters were determined by a non-linear mixed effects modeling approach. It was demonstrated that thermoresponsive hydrogel with heparin/chitosan nanocomplexes enabled the lowest absorption rate of heparin into systemic circulation and provided heparin concentration above the prophylaxis threshold for 5 days. In situ gelling thermoresponsive matrix combined with chitosan nanocomplexes present a promising delivery system for heparin, requiring less frequent administration during long-term treatment.
2015
http://www.sciencedirect.com/science/journal/03785173
File in questo prodotto:
File Dimensione Formato  
lavoro istok2015.pdf

Accesso chiuso

Descrizione: pdf articolo pubblicato
Tipologia: Documento in Versione Editoriale
Licenza: Digital Rights Management non definito
Dimensione 2.53 MB
Formato Adobe PDF
2.53 MB Adobe PDF   Visualizza/Apri   Richiedi una copia
mmc1 (2).pdf

Accesso chiuso

Descrizione: pdf supplementary material
Tipologia: Altro materiale allegato
Licenza: Digital Rights Management non definito
Dimensione 25.7 kB
Formato Adobe PDF
25.7 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
Submitted version.pdf

accesso aperto

Descrizione: post print
Tipologia: Bozza finale post-referaggio (post-print)
Licenza: Digital Rights Management non definito
Dimensione 1.06 MB
Formato Adobe PDF
1.06 MB Adobe PDF Visualizza/Apri
Supplementary data.pdf

accesso aperto

Descrizione: supplementary data in post print
Tipologia: Bozza finale post-referaggio (post-print)
Licenza: Digital Rights Management non definito
Dimensione 371.69 kB
Formato Adobe PDF
371.69 kB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11368/2870217
Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 10
  • ???jsp.display-item.citation.isi??? 7
social impact