Hypopharyngeal and cervical esophageal strictures can be caused by advanced malignancies, ingestion of caustic materials, or can follow surgery or radiation therapy. They cause marked dysphagia and consequently patients need nasogastric or gastrostomy tube feeding, with a remarkable impact on quality of life. To restore oral feeding, the stenosis can be progressively dilated by using rubber bougies of increasing diameter, and a Montgomery® Salivary Bypass Tube can then be inserted to maintain the obtained calibre. However, while its flexibility makes it easy to tolerate, it has the drawback of making insertion difficult because the tube tends to bend. The aim of this paper is to present a possible solution to this problem. A Montgomery® Salivary Bypass Tube was distally sutured to a Cook Airway Exchange Catheter® to simplify its initial insertion through a laryngoscope and following replacements. The catheter was then easily removed leaving the bypass tube in the correct position. In our experience, this innovative approach proved effective in facilitating Montgomery® Salivary Bypass Tube insertion in three patients, without risks for the patient, additional operative time or increase in costs.

Salivary bypass tube placement in esophageal stricture: A technical note and report of three cases

TIRELLI, GIAN CARLO;BOSCOLO NATA, FRANCESCA
2016-01-01

Abstract

Hypopharyngeal and cervical esophageal strictures can be caused by advanced malignancies, ingestion of caustic materials, or can follow surgery or radiation therapy. They cause marked dysphagia and consequently patients need nasogastric or gastrostomy tube feeding, with a remarkable impact on quality of life. To restore oral feeding, the stenosis can be progressively dilated by using rubber bougies of increasing diameter, and a Montgomery® Salivary Bypass Tube can then be inserted to maintain the obtained calibre. However, while its flexibility makes it easy to tolerate, it has the drawback of making insertion difficult because the tube tends to bend. The aim of this paper is to present a possible solution to this problem. A Montgomery® Salivary Bypass Tube was distally sutured to a Cook Airway Exchange Catheter® to simplify its initial insertion through a laryngoscope and following replacements. The catheter was then easily removed leaving the bypass tube in the correct position. In our experience, this innovative approach proved effective in facilitating Montgomery® Salivary Bypass Tube insertion in three patients, without risks for the patient, additional operative time or increase in costs.
2016
12-dic-2016
Pubblicato
http://www.sciencedirect.com/science/article/pii/S0385814616303182?via%3Dihub
File in questo prodotto:
File Dimensione Formato  
1-s2.0-S0385814616303182-main.pdf

Accesso chiuso

Tipologia: Documento in Versione Editoriale
Licenza: Digital Rights Management non definito
Dimensione 1.04 MB
Formato Adobe PDF
1.04 MB Adobe PDF   Visualizza/Apri   Richiedi una copia
Tirelli.pdf

Open Access dal 16/12/2017

Tipologia: Bozza finale post-referaggio (post-print)
Licenza: Digital Rights Management non definito
Dimensione 935.19 kB
Formato Adobe PDF
935.19 kB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11368/2909037
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 3
  • ???jsp.display-item.citation.isi??? 3
social impact