Paclitaxel belongs to the taxanes family and it is used, alone or in multidrug regimens, for the therapy of several solid tumours, such as breast-, lung-, head and neck-, and ovarian cancer. Standard dosing of chemotherapy does not take into account the many inter-patient differences that make drug exposure highly variable, thus leading to the insurgence of severe toxicity. This is particularly true for paclitaxel considering that a relationship between haematological toxicity and plasma exposure was found. Therefore, in order to treat patients with the correct dose of paclitaxel, improving the overall benefit-risk ratio, Therapeutic Drug Monitoring is necessary. In order to quantify paclitaxel and its main metabolite, 6α-hydroxy-paclitaxel, in patients' plasma, we developed a new, sensitive and specific HPLC-MS/MS method applicable to all paclitaxel dosages used in clinical routine. The developed method used a small volume of plasma sample and is based on quick protein precipitation. The chromatographic separation of the analytes was achieved with a SunFire™ C18 column (3.5 μM, 92 Å, 2,1 x 150 mm); the mobile phases were 0.1% formic acid/bidistilled water and 0.1% formic acid/acetonitrile. The electrospray ionization source worked in positive ion mode and the mass spectrometer operated in selected reaction monitoring mode. Our bioanalytical method was successfully validated according to the FDA-EMA guidelines on bioanalytical method validation. The calibration curves resulted linear (R2 ≥0.9948) over the concentration ranges (1-10000 ng/mL for paclitaxel and 1-1000 ng/mL for 6α-hydroxy-paclitaxel) and were characterized by a good accuracy and precision. The intra- and inter-day precision and accuracy were determined on three quality control concentrations for paclitaxel and 6α-hydroxy-paclitaxel and resulted respectively <9.9% and within 91.1-114.8%. In addition, to further verify the assay reproducibility, we tested this method by re-analysing the incurred samples. This bioanalytical method was employed with success to a genotype-guided phase Ib study of weekly paclitaxel in ovarian cancer patients treated with a wide range of drug's dosages.

A new high-performance liquid chromatography-tandem mass spectrometry method for the determination of paclitaxel and 6α-hydroxy-paclitaxel in human plasma: Development, validation and application in a clinical pharmacokinetic study

Posocco, Bianca;Buzzo, Mauro;Toffoli, Giuseppe
2018-01-01

Abstract

Paclitaxel belongs to the taxanes family and it is used, alone or in multidrug regimens, for the therapy of several solid tumours, such as breast-, lung-, head and neck-, and ovarian cancer. Standard dosing of chemotherapy does not take into account the many inter-patient differences that make drug exposure highly variable, thus leading to the insurgence of severe toxicity. This is particularly true for paclitaxel considering that a relationship between haematological toxicity and plasma exposure was found. Therefore, in order to treat patients with the correct dose of paclitaxel, improving the overall benefit-risk ratio, Therapeutic Drug Monitoring is necessary. In order to quantify paclitaxel and its main metabolite, 6α-hydroxy-paclitaxel, in patients' plasma, we developed a new, sensitive and specific HPLC-MS/MS method applicable to all paclitaxel dosages used in clinical routine. The developed method used a small volume of plasma sample and is based on quick protein precipitation. The chromatographic separation of the analytes was achieved with a SunFire™ C18 column (3.5 μM, 92 Å, 2,1 x 150 mm); the mobile phases were 0.1% formic acid/bidistilled water and 0.1% formic acid/acetonitrile. The electrospray ionization source worked in positive ion mode and the mass spectrometer operated in selected reaction monitoring mode. Our bioanalytical method was successfully validated according to the FDA-EMA guidelines on bioanalytical method validation. The calibration curves resulted linear (R2 ≥0.9948) over the concentration ranges (1-10000 ng/mL for paclitaxel and 1-1000 ng/mL for 6α-hydroxy-paclitaxel) and were characterized by a good accuracy and precision. The intra- and inter-day precision and accuracy were determined on three quality control concentrations for paclitaxel and 6α-hydroxy-paclitaxel and resulted respectively <9.9% and within 91.1-114.8%. In addition, to further verify the assay reproducibility, we tested this method by re-analysing the incurred samples. This bioanalytical method was employed with success to a genotype-guided phase Ib study of weekly paclitaxel in ovarian cancer patients treated with a wide range of drug's dosages.
File in questo prodotto:
File Dimensione Formato  
journal.pone.0193500.pdf

accesso aperto

Descrizione: articolo principale
Tipologia: Documento in Versione Editoriale
Licenza: Creative commons
Dimensione 2.55 MB
Formato Adobe PDF
2.55 MB Adobe PDF Visualizza/Apri
supp. inf..pdf

accesso aperto

Descrizione: supporting information
Tipologia: Altro materiale allegato
Licenza: Creative commons
Dimensione 311.77 kB
Formato Adobe PDF
311.77 kB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11368/2931941
Citazioni
  • ???jsp.display-item.citation.pmc??? 6
  • Scopus 14
  • ???jsp.display-item.citation.isi??? 13
social impact