Objective.Differentiation of breast tissues is challenging in X-ray imaging because tissues might share similar or even the same linear attenuation coefficientsμ. Spectral computed tomography (CT) allows for more quantitative characterization in terms of tissue density (ρ) and effective atomic number (Zeff) by exploiting the energy dependence ofμ. The objective of this study was to examine the potential ofρ/Zeffdecomposition in spectral breast CT so as to explore the benefits of tissue characterization and improve the diagnostic accuracy of this emerging 3D imaging technique.Approach.In this work, 5 mastectomy samples and a phantom with inserts mimicking breast soft tissues were evaluated in a retrospective study. The samples were imaged at three monochromatic energy levels in the range of 24-38 keV at 5 mGy per scan using a propagation-based phase-contrast setup at SYRMEP beamline at the Italian national synchrotron Elettra.Main results.A custom-made algorithm incorporating CT reconstructions of an arbitrary number of spectral energy channels was developed to extract the density and effective atomic number of adipose, fibro-glandular, pure glandular, tumor, and skin from regions selected by a radiologist.Significance.Preliminary results suggest that, via spectral CT, it is possible to enhance tissue differentiation. It was found that adipose, fibro-glandular and tumorous tissues have average effective atomic numbers (5.94 ± 0.09, 7.03 ± 0.012, and 7.40 ± 0.10) and densities (0.90 ± 0.02, 0.96 ± 0.02, and 1.07 ± 0.03 g cm-3) and can be better distinguished if both quantitative values are observed together.
Characterization of breast tissues in density and effective atomic number basis via spectral X-ray computed tomography
Vrbaski, Stevan;Arana Peña, Lucia Mariel;Brombal, Luca;Donato, Sandro;Taibi, Angelo;Longo, Renata
2023-01-01
Abstract
Objective.Differentiation of breast tissues is challenging in X-ray imaging because tissues might share similar or even the same linear attenuation coefficientsμ. Spectral computed tomography (CT) allows for more quantitative characterization in terms of tissue density (ρ) and effective atomic number (Zeff) by exploiting the energy dependence ofμ. The objective of this study was to examine the potential ofρ/Zeffdecomposition in spectral breast CT so as to explore the benefits of tissue characterization and improve the diagnostic accuracy of this emerging 3D imaging technique.Approach.In this work, 5 mastectomy samples and a phantom with inserts mimicking breast soft tissues were evaluated in a retrospective study. The samples were imaged at three monochromatic energy levels in the range of 24-38 keV at 5 mGy per scan using a propagation-based phase-contrast setup at SYRMEP beamline at the Italian national synchrotron Elettra.Main results.A custom-made algorithm incorporating CT reconstructions of an arbitrary number of spectral energy channels was developed to extract the density and effective atomic number of adipose, fibro-glandular, pure glandular, tumor, and skin from regions selected by a radiologist.Significance.Preliminary results suggest that, via spectral CT, it is possible to enhance tissue differentiation. It was found that adipose, fibro-glandular and tumorous tissues have average effective atomic numbers (5.94 ± 0.09, 7.03 ± 0.012, and 7.40 ± 0.10) and densities (0.90 ± 0.02, 0.96 ± 0.02, and 1.07 ± 0.03 g cm-3) and can be better distinguished if both quantitative values are observed together.File | Dimensione | Formato | |
---|---|---|---|
pmb_68_14_145019.pdf
accesso aperto
Tipologia:
Documento in Versione Editoriale
Licenza:
Creative commons
Dimensione
1.14 MB
Formato
Adobe PDF
|
1.14 MB | Adobe PDF | Visualizza/Apri |
Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.