Real-life data comparing the long-term outcome in patients with different heart diseases carrying an implantable cardioverter defibrillator (ICD) are scarce. This study aimed to compare the long-term risk of the first appropriate ICD intervention and overall survival in patients with ICD and heart disease of different etiologies. Patients with an ICD implanted between January 1, 2010, and December 31, 2022, followed in our center were included. Study outcomes were all-cause mortality and first appropriate ICD intervention. A comparison between ischemic heart disease (IHD) and non-IHD (NIHD) was performed. In NIHD different etiologies of dilated cardiomyopathy (DCM) were analyzed. Overall, 1184 patients (592 IDH; 592 NIHD) were included. During a median follow-up of 53 months all-cause death occurred in 399 patients (34%) whereas first appropriate ICD intervention occurred in 320 (27%). All-cause mortality was significantly higher in IHD vs NIHD patients (60% vs 43%; p <0.0001) but no differences in appropriate ICD intervention rate at 10 years (34% vs 40%; p = 0.125) were observed. In patients with NIHD, a higher 10-year mortality rate was found in valvular heart disease, post-radio/chemotherapy DCM (rctDCM), and hypertensive DCM. Hypertrophic cardiomyopathy, alcoholic DCM, and rctDCM were the least arrhythmic phenotypes in NIHD. Of note, inappropriate interventions in alcoholic DCM and rctDCM were higher than appropriate ones. In conclusion, the rate of ICD-appropriate interventions and mortality is different according to the etiology of heart disease and cardiovascular risk profile; this should be taken into consideration in the prognostic stratification of these patients at the time of implantation.

Long-Term Outcomes in ICD: All-Causes Mortality and First Appropriate Intervention in Ischemic and Nonischemic Etiologies

Cittar, Marco
Primo
;
Zecchin, Massimo
Secondo
;
Merlo, Marco;Baggio, Chiara;Carriere, Cosimo;Pagura, Linda;Barbati, Giulia;Sinagra, Gianfranco
Ultimo
2024-01-01

Abstract

Real-life data comparing the long-term outcome in patients with different heart diseases carrying an implantable cardioverter defibrillator (ICD) are scarce. This study aimed to compare the long-term risk of the first appropriate ICD intervention and overall survival in patients with ICD and heart disease of different etiologies. Patients with an ICD implanted between January 1, 2010, and December 31, 2022, followed in our center were included. Study outcomes were all-cause mortality and first appropriate ICD intervention. A comparison between ischemic heart disease (IHD) and non-IHD (NIHD) was performed. In NIHD different etiologies of dilated cardiomyopathy (DCM) were analyzed. Overall, 1184 patients (592 IDH; 592 NIHD) were included. During a median follow-up of 53 months all-cause death occurred in 399 patients (34%) whereas first appropriate ICD intervention occurred in 320 (27%). All-cause mortality was significantly higher in IHD vs NIHD patients (60% vs 43%; p <0.0001) but no differences in appropriate ICD intervention rate at 10 years (34% vs 40%; p = 0.125) were observed. In patients with NIHD, a higher 10-year mortality rate was found in valvular heart disease, post-radio/chemotherapy DCM (rctDCM), and hypertensive DCM. Hypertrophic cardiomyopathy, alcoholic DCM, and rctDCM were the least arrhythmic phenotypes in NIHD. Of note, inappropriate interventions in alcoholic DCM and rctDCM were higher than appropriate ones. In conclusion, the rate of ICD-appropriate interventions and mortality is different according to the etiology of heart disease and cardiovascular risk profile; this should be taken into consideration in the prognostic stratification of these patients at the time of implantation.
File in questo prodotto:
File Dimensione Formato  
1-s2.0-S0002914924007045-main.pdf

Accesso chiuso

Tipologia: Documento in Versione Editoriale
Licenza: Copyright Editore
Dimensione 1.27 MB
Formato Adobe PDF
1.27 MB Adobe PDF   Visualizza/Apri   Richiedi una copia
1-s2.0-S0002914924007045-mmc1.pdf

Accesso chiuso

Tipologia: Altro materiale allegato
Licenza: Copyright Editore
Dimensione 312.46 kB
Formato Adobe PDF
312.46 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11368/3095398
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact