Purpose: To evaluate retrospectively the 2-year outcomes of the Gore Excluder Iliac Branch Endoprosthesis (IBE) in patients with and without coexisting hypogastric artery (HA) aneurysms in a large contemporary multicentric European experience using dedicated bridging devices. Methods: The study included all consecutive patients treated at participating institutions with the Gore Excluder IBE device who received a covered stent (i.e., stent-graft) from the same manufacturer. Technical success was defined as deployment of endografts with complete exclusion of the aneurysm(s), patency of target vessels, and absence of type 1 and 3 endoleak. Assessment of follow-up outcomes included freedom from HA branch instability defined as the composite cumulative endpoint of any HA branch-related complication. Results: A total of 437 patients were included for analysis from 22 European vascular surgery centers. Patients were categorized into two subgroups: subgroup A (n = 269) if they did not have concomitant hypogastric aneurysms, otherwise they were categorized into subgroup B (n = 168). Finally, 78 (18%) had bilateral IBE with a total of 515 IBE included in the study. Balloon expandable stents were deployed in 19 (6.3%) subgroup A patients compared with 46 (21.7%,) in subgroup B, p < .001. The two-year estimate for freedom of HA branch instability was significantly higher for patients in group A as compared with patients in group B (94% vs. 90%, p = .045). At univariate regression, the number of stent-grafts used was associated with higher risk of iliac branch instability (p = .021), while in multivariate regression for the use of more than 2 bridging stent-grafts the risk of instability increased by 2.35 times. Conclusions: This large contemporary European multicentric experience with the use of the Gore Excluder IBE in patients with or without associated HA aneurysms shows satisfactory mid-term outcomes when the device is used in conjunction with both self-expandable and balloon-expanding stent-grafts from the same manufacturer. Although primary patency of the iliac branch was as high as 90%, caution and strict follow-up must be exercised when multiple bridging stent-grafts are used over longer distances.
Mid-Term Outcomes of the Iliac Branch Endoprosthesis with Standardized Combinations of Bridging Stent-Grafts for Endovascular Treatment of Aortoiliac Disease with or Without Co-existing Hypogastric Aneurysms (The HYPROTECT Study) / D'Oria, Mario; Pitoulias, Georgios; Lepidi, Sandro; Bellosta, Raffaello; Reijnen, Michel M. P. J.; Simonte, Gioele; Pratesi, Giovanni; Usai, Marco V.; Gargiulo, Mauro; Dias, Nuno; Ferrer, Ciro; Benedetto, Filippo; Veraldi, Gian Franco; Duppers, Philip; Noya, Jorge F.; Wiersema, Arno; Spanos, Konstantinos; Troisi, Nicola; Moniaci, Diego; Antonello, Michele; Trimarchi, Santi; De Vries, Jean-Paul; Abisi, Said; Pitoulias, Apostolos; Taneva, Gergana T.; Donas, Konstantinos P.; Hyprotect Study, Group; Attisani, Luca; Austermann, Martin; Bastianon, Martina; Berchiolli, Raffaella; Bissacco, Daniele; Calvagna, Cristiano; Colacchio, Chiara Elda; Fittipaldi, Alessandra; Fulgheri, Irene; Gallitto, Enrico; Giudice, Rocco; Grando, Beatrice; Harishankar, Nair; Isernia, Giacomo; Karelis, Angelos; Lomazzi, Chiara; Mastrorilli, Davide; Vera, Jorge Miguel Mena; Matsagkas, Miltiadis; Mezzetto, Luca; Mitta, Nivedita; Parlani, Gianbattista; Peretti, Tania; Shehada, Yousef; Taglialavoro, Jacopo; Terpin, Andrea Maria; Tielliu, Ignace; Zimmermann, Alexander. - In: CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY. - ISSN 0174-1551. - 47:12(2024), pp. 1739-1749. [10.1007/s00270-024-03881-z]
Mid-Term Outcomes of the Iliac Branch Endoprosthesis with Standardized Combinations of Bridging Stent-Grafts for Endovascular Treatment of Aortoiliac Disease with or Without Co-existing Hypogastric Aneurysms (The HYPROTECT Study)
D'Oria, Mario
Primo
;Lepidi, Sandro;
2024-01-01
Abstract
Purpose: To evaluate retrospectively the 2-year outcomes of the Gore Excluder Iliac Branch Endoprosthesis (IBE) in patients with and without coexisting hypogastric artery (HA) aneurysms in a large contemporary multicentric European experience using dedicated bridging devices. Methods: The study included all consecutive patients treated at participating institutions with the Gore Excluder IBE device who received a covered stent (i.e., stent-graft) from the same manufacturer. Technical success was defined as deployment of endografts with complete exclusion of the aneurysm(s), patency of target vessels, and absence of type 1 and 3 endoleak. Assessment of follow-up outcomes included freedom from HA branch instability defined as the composite cumulative endpoint of any HA branch-related complication. Results: A total of 437 patients were included for analysis from 22 European vascular surgery centers. Patients were categorized into two subgroups: subgroup A (n = 269) if they did not have concomitant hypogastric aneurysms, otherwise they were categorized into subgroup B (n = 168). Finally, 78 (18%) had bilateral IBE with a total of 515 IBE included in the study. Balloon expandable stents were deployed in 19 (6.3%) subgroup A patients compared with 46 (21.7%,) in subgroup B, p < .001. The two-year estimate for freedom of HA branch instability was significantly higher for patients in group A as compared with patients in group B (94% vs. 90%, p = .045). At univariate regression, the number of stent-grafts used was associated with higher risk of iliac branch instability (p = .021), while in multivariate regression for the use of more than 2 bridging stent-grafts the risk of instability increased by 2.35 times. Conclusions: This large contemporary European multicentric experience with the use of the Gore Excluder IBE in patients with or without associated HA aneurysms shows satisfactory mid-term outcomes when the device is used in conjunction with both self-expandable and balloon-expanding stent-grafts from the same manufacturer. Although primary patency of the iliac branch was as high as 90%, caution and strict follow-up must be exercised when multiple bridging stent-grafts are used over longer distances.| File | Dimensione | Formato | |
|---|---|---|---|
|
s00270-024-03881-z.pdf
Accesso chiuso
Tipologia:
Documento in Versione Editoriale
Licenza:
Copyright Editore
Dimensione
815.55 kB
Formato
Adobe PDF
|
815.55 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |
Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.